Mega Power MP-13030HWG-250 | 250 Amps 13 Hp Honda Electric Start Welder/Generator/Air Compressor

Model: MP-13030HWG-250

The Megapower MP-13030HWG is a versatile and powerful 3-in-1 machine, functioning as an air compressor, generator, and welder, making it ideal for various industrial and DIY applications. It is powered by a robust Honda GX390 engine, offering 13 horsepower for reliable performance. As an air compressor, it delivers impressive capabilities with 28 CFM displaced and 18.0 CFM at 175 PSI, featuring a splash lubrication system and a 61-ounce pump oil capacity.

Its welding functionality provides a range of 170 to 200 AMP, catering to different welding needs. The unit also serves as a generator with a 5.5 KW output, suitable for a variety of power requirements. The tank capacity stands at 30 gallons, complying with ASME standards, and the overall unit has a substantial shipping weight of 650 pounds. This combination of features ensures that the MP-13030HWG is a valuable tool for both professional and personal use, offering reliability, power, and versatility.

Weld Output Terminals

  • Welding Amperes and Cable Size Recommendations:

    • For 100 Amperes:
      • Up to 100 ft: Use 4 AWG
      • Up to 150 ft: Use 4 AWG
      • Up to 200 ft: Use 3 AWG
      • Up to 250 ft: Use 2 AWG
      • Up to 300 ft: Use 1 AWG
      • Up to 350 ft: Use 1/0 AWG
      • Up to 400 ft: Use 1/0 AWG
    • For 150 Amperes:
      • [Similar progression with appropriate AWG sizes]
    • For 200 Amperes:
      • [Similar progression with appropriate AWG sizes]
  • General Guidelines:

    • If cable overheats, use the next larger size.
    • Cable size is based on a 4-volt or less drop or a current density of at least 300 circular mils per ampere.
    • [Metric conversion information]

The weld output terminal chart for the Megapower MP-13030HWG provides a general guideline for selecting weld cable sizes based on the total cable length and welding amperes. It is essential to understand that this chart serves as a basic reference and may not be suitable for every application. In cases where the cable overheats, it is advised to opt for the next larger cable size. Additionally, the selection of weld cable size (AWG) is determined by a combination of factors including a voltage drop of 4 volts or less and a current density of at least 300 circular mils per ampere, with a conversion to mm2 for metric usage. For precise and detailed information, it's recommended to consult the original document or seek professional guidance

    Not Included are these additional accessories

    Add The Stinger, Ground Clamp and Cables.

       

      Mega Power MP-13030HWGU-250 13 Hp Honda Electric Start Welder/Generator/Air Compressor  | Accessories Included

       

      Must have forklift or loading dock At your business address for this to ship to

      View our website  www.repquip.com for other New and Used Equipment we sell.


      WARNING: This product may expose you to chemicals including lead which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

      Mega Power MP-13030HWG-250 | 250 Amps 13 Hp Honda Electric Start Welder/Generator/Air Compressor

      Model: MP-13030HWG-250

      The Megapower MP-13030HWG is a versatile and powerful 3-in-1 machine, functioning as an air compressor, generator, and welder, making it ideal for various industrial and DIY applications. It is powered by a robust Honda GX390 engine, offering 13 horsepower for reliable performance. As an air compressor, it delivers impressive capabilities with 28 CFM displaced and 18.0 CFM at 175 PSI, featuring a splash lubrication system and a 61-ounce pump oil capacity.

      Its welding functionality provides a range of 170 to 200 AMP, catering to different welding needs. The unit also serves as a generator with a 5.5 KW output, suitable for a variety of power requirements. The tank capacity stands at 30 gallons, complying with ASME standards, and the overall unit has a substantial shipping weight of 650 pounds. This combination of features ensures that the MP-13030HWG is a valuable tool for both professional and personal use, offering reliability, power, and versatility.

      Weld Output Terminals

      • Welding Amperes and Cable Size Recommendations:

        • For 100 Amperes:
          • Up to 100 ft: Use 4 AWG
          • Up to 150 ft: Use 4 AWG
          • Up to 200 ft: Use 3 AWG
          • Up to 250 ft: Use 2 AWG
          • Up to 300 ft: Use 1 AWG
          • Up to 350 ft: Use 1/0 AWG
          • Up to 400 ft: Use 1/0 AWG
        • For 150 Amperes:
          • [Similar progression with appropriate AWG sizes]
        • For 200 Amperes:
          • [Similar progression with appropriate AWG sizes]
      • General Guidelines:

        • If cable overheats, use the next larger size.
        • Cable size is based on a 4-volt or less drop or a current density of at least 300 circular mils per ampere.
        • [Metric conversion information]

      The weld output terminal chart for the Megapower MP-13030HWG provides a general guideline for selecting weld cable sizes based on the total cable length and welding amperes. It is essential to understand that this chart serves as a basic reference and may not be suitable for every application. In cases where the cable overheats, it is advised to opt for the next larger cable size. Additionally, the selection of weld cable size (AWG) is determined by a combination of factors including a voltage drop of 4 volts or less and a current density of at least 300 circular mils per ampere, with a conversion to mm2 for metric usage. For precise and detailed information, it's recommended to consult the original document or seek professional guidance

        Not Included are these additional accessories

        Add The Stinger, Ground Clamp and Cables.

           

          Mega Power MP-13030HWGU-250 13 Hp Honda Electric Start Welder/Generator/Air Compressor  | Accessories Included

           

          Must have forklift or loading dock At your business address for this to ship to

          • Model: MP-13030HWG, a 3-in-1 Air Compressor, Generator, and Welder.
          • Engine: Honda GX390 with 13 Horse Power.
          • Air Compressor Performance:
          • CFM Displaced: 28 CFM.
          • CFM Delivered: 18.0 CFM at 175 PSI.
          • Lubrication: Splash Lubrication system.
          • Pump Oil Capacity: 61 ounces.
          • Welder Capacity:
          • Standard: 170 AMP.
          • Maximum: 200 AMP.
          • Generator Output: 5.5 KW.
          • Tank Capacity: 30 Gallons (ASME certified).
          • Shipping Weight: 650 pounds.

           

          Must have forklift or loading dock At your business address for this to ship to

          This Item Qualifies for FREE LTL SHIPPING  (via Truck)  it applies only to destinations within the 48 contiguous United States. Alaska, Hawaii, and any/all US territories and international orders are excluded.

          LTL Freight Shipping Options 
          • LIMITED ACCESS - commercial / non-commercial / Farms(+ $85.00)
          • Lift Gate Is Required.(+$150.00)
          • I have a forklift for unloading Freight at My Business location
          • I have a way of unloading Freight at my location
          • Deliver to local freight terminal for pickup.

          Please select one of the choices above BEFORE adding to the cart!

          Important Shipping & Order Pricessing Times

          • 🚀 Next Day Air Shipping:
            Place your order before 11:00 AM EST on Fridays to ensure same-day processing. Orders placed after this time will be processed on the next business day.

          • 🕒 Order Processing Times:
            Orders placed Monday through Thursday after 12:00 PM EST, whether shipping by Air or Ground, will be processed on the following business day.

          PLEASE NOTE:
          This item ships by truck.
          If you Require to ship to a Non-Commercial Address, please email
          or call (855) 320 7276 us so we can give you an updated shipping Quote.

          Please Review our Terms of Service, Shipping Policy, Return & Refund, Policy Pages.

          What is LIMITED ACCESS

          Limited access charges were created to compensate LTL carriers for additional time spent at a shipments' pick up or delivery locations and constraints that can result from these specific locations. Limited access is defined as meeting any of the following conditions:

          • Not open to the walk-in public during normal business hours
          • Not having personnel readily available to assist with the delivery or pickup function
          • Not having access to loading dock or platform
          • Sites where carriers are delayed with security related inspections and processes prior to freight tender

          Did you know: Some of these high security locations will ask for a driver’s license and drivers have the right to refuse to do so? This causes the carrier to find a driver who is willing to do so, which in turn causes a domino effect or constraint on the daily operations of that particular terminal.

          In order to avoid unexpected charges it is best practice to ask the consignee if they have a dock or way to unload the freight and ask them if they need a liftgate for delivery. Liftgates are commonly associated with limited access and if the consignee advises they don’t need a liftgate let them know that if the driver offers a liftgate and if it is used or signed for even though it was not used, there will be an additional fee charged to them.

          Limited access fees can be assessed on both commercial and non-commercial delivery sites. Charges and what constitutes as a limited access will vary based on carrier, but here are some of the most common examples:

          • Camps, Carnivals, Fairs
          • Churches, Mosques, Synagogues, Temples
          • Schools (not including colleges and universities)
          • Colleges and Universities without a dock
          • Medical/Urgent care sites without a dock
          • Prisons
          • Individual / Mini Storage Units
          • Mines, Quarries, Natural Gas or Oil Fields
          • Golf Courses, Country Clubs
          • Nuclear Power Plants
          • Military Bases/Installations
          • Parks, Farms and Rural locations
          • Courthouses
          • Daycares
          • Hotels, Motels, Retirement/Nursing Homes
          • Restaurants
          • Cemeteries
          • Convents
          • Amusement Parks
          • Construction Sites
          • Outdoor Flea Markets

          Google Maps is a great tool that can be used to help explain whether or not a location has limited access. However, please keep in mind that even though the location is easy to get in and out of and they may have the necessary equipment to unload they may still be considered limited access. Some great examples of this are as follows:

          • Farms: While they are easy to get to and have equipment, they usually take the driver off his/her usual route which causes delays for the other shipments on the trailer
          • Mini Storage Units: The driver will have to use a smaller trailer with or without a liftgate and thus make fewer deliveries that day because of the space available on the trailer, so the charges are there to compensate for this
          • Carriers normally have fewer trailers with liftgates which makes this even more difficult when the volume of limited access or liftgate shipments goes up

          Keep in mind: Commercial buildings with docks are normally clustered in the same area, a carrier can easily make multiple pickups or deliveries in a business park in the same time it may take to make one limited access delivery.

          Customer Reviews

          Be the first to write a review
          0%
          (0)
          0%
          (0)
          0%
          (0)
          0%
          (0)
          0%
          (0)