Flo-Dynamics CMS-240 Heavy Duty Coolant Maintenance System, 40-gallon Tank
- Product SKU: 40400056
Important Shipping Information:-
• Orders received on Fridays after 11am EST will be processed the next business day
• All orders shipped to a RESIDENTIAL ADDRESS will be subject to Additional charges from all carriers at this time.
• What is LIMITED ACCESS - Commercial / Non-Commercial / Farms Click Here to Read More
Financing From Low As $158 per Month
Flo-Dynamics CMS-240 Heavy Duty Coolant Maintenance System, 40-gallon Tank
MODEL : CMS-240
PART NO: 40400056
Crafted with precision and the technician's needs in mind, the CMS-240 Coolant Maintenance System by Flo-Dynamics revolutionizes coolant servicing tasks. Whether it’s draining, filling, or a complete coolant exchange, the CMS-240 delivers unrivaled speed and efficiency for large capacity cooling systems.
Key Features:
-
High Capacity Dual Tanks: Equipped with two 40-gallon tanks, clearly marked for “used” and “new” coolant, allowing for uninterrupted operations.
-
Push/Pull Technology: This advanced system uses both pressure and vacuum, drastically reducing the time for draining and filling processes. A 14-gallon cooling system can be drained in approximately 10 minutes and refilled without air pockets in about 13 minutes.
-
Full Coolant Exchange: With separate tanks, execute a complete coolant exchange for a 14-gallon system in under 14 minutes, with no air bleeding, hose switching, or lengthy wait times.
-
Enhanced Mobility: Its design boasts an easy mobility cart fitted with robust 8” casters, ensuring smooth movement around the workshop.
-
Power Efficient: Solely powered by 115 psi shop air, the CMS-240 forgoes the need for additional electrical sources.
-
Coolant Filtration: As it drains, the system filters and cleans the coolant, ensuring that contaminants are removed.
-
Visibility and Durability: A fluid level sight tube is integrated for easy coolant level monitoring. The internally coated tank wards off rust, ensuring longevity.
-
Advanced Hose System: The 13’ polyurethane service hoses are durable and designed for easy service switching with a simple valve turn.
-
Flush-Face Quick Connect Couplers: Available for seamless and swift connection to various vehicles.
Conclusion:
For the modern workshop aiming to provide unparalleled service and maintain high operational efficiency, the CMS-240 Coolant Maintenance System is the ultimate choice. Combining rapid performance, ease of use, and state-of-the-art features, this system streamlines the cooling system servicing process, enhancing productivity and customer satisfaction. Choose CMS-240 — the next generation in coolant maintenance.
View our website www.repquip.com for other New and Used Equipment we sell.
Flo-Dynamics CMS-240 Heavy Duty Coolant Maintenance System, 40-gallon Tank
MODEL : CMS-240
PART NO: 40400056
Crafted with precision and the technician's needs in mind, the CMS-240 Coolant Maintenance System by Flo-Dynamics revolutionizes coolant servicing tasks. Whether it’s draining, filling, or a complete coolant exchange, the CMS-240 delivers unrivaled speed and efficiency for large capacity cooling systems.
Key Features:
-
High Capacity Dual Tanks: Equipped with two 40-gallon tanks, clearly marked for “used” and “new” coolant, allowing for uninterrupted operations.
-
Push/Pull Technology: This advanced system uses both pressure and vacuum, drastically reducing the time for draining and filling processes. A 14-gallon cooling system can be drained in approximately 10 minutes and refilled without air pockets in about 13 minutes.
-
Full Coolant Exchange: With separate tanks, execute a complete coolant exchange for a 14-gallon system in under 14 minutes, with no air bleeding, hose switching, or lengthy wait times.
-
Enhanced Mobility: Its design boasts an easy mobility cart fitted with robust 8” casters, ensuring smooth movement around the workshop.
-
Power Efficient: Solely powered by 115 psi shop air, the CMS-240 forgoes the need for additional electrical sources.
-
Coolant Filtration: As it drains, the system filters and cleans the coolant, ensuring that contaminants are removed.
-
Visibility and Durability: A fluid level sight tube is integrated for easy coolant level monitoring. The internally coated tank wards off rust, ensuring longevity.
-
Advanced Hose System: The 13’ polyurethane service hoses are durable and designed for easy service switching with a simple valve turn.
-
Flush-Face Quick Connect Couplers: Available for seamless and swift connection to various vehicles.
Conclusion:
For the modern workshop aiming to provide unparalleled service and maintain high operational efficiency, the CMS-240 Coolant Maintenance System is the ultimate choice. Combining rapid performance, ease of use, and state-of-the-art features, this system streamlines the cooling system servicing process, enhancing productivity and customer satisfaction. Choose CMS-240 — the next generation in coolant maintenance.
- Dimensions: 56” H x 28” W x 54” D
- Weight: 288 lb.
- Fluid Tanks: Dual 40-gallon capacity (one for "used" coolant, one for "new" coolant)
- Power Source: 115 psi shop air
- Hose Length: 13' outside of the machine
- Coolant Drain Time: Approximately 10 minutes for a 14-gallon system
- Coolant Refill Time: Approximately 13 minutes for a 14-gallon system (air pocket-free)
- Complete Coolant Exchange: Under 14 minutes for a 14-gallon system (fully air bled)
- Hose Material: 13’ polyurethane service hoses
- Tank Coating: Internally coated to prevent rust contamination
- Mobility: Heavy-duty 8” casters
- Connectivity: Flush-face quick connect couplers available
- Operation: Functions on shop air, eliminating the need for 120V or 12V power
These specifications provide a comprehensive overview of the CMS-240's capabilities, highlighting its technical details and operational efficiency.
This Item Qualifies for FREE LTL SHIPPING (via Truck) it applies only to destinations within the 48 contiguous United States. Alaska, Hawaii, and any/all US territories and international orders are excluded.
LTL Freight Shipping Options- LIMITED ACCESS - commercial / non-commercial / Farms(+ $85.00)
- Lift Gate Is Required.(+$150.00)
- I have a forklift for unloading Freight at My Business location
- I have a way of unloading Freight at my location
- Deliver to local freight terminal for pickup.
Please select one of the choices above BEFORE adding to the cart!
PLEASE NOTE:
This item ships by truck. If you Require to ship to a Non-Commercial Address, please email
or call (855) 320 7276 us so we can give you an updated shipping Quote.
Please Review our Terms of Service, Shipping Policy, Return & Refund, Policy Pages.
What is LIMITED ACCESS
Limited access charges were created to compensate LTL carriers for additional time spent at a shipments' pick up or delivery locations and constraints that can result from these specific locations. Limited access is defined as meeting any of the following conditions:
- Not open to the walk-in public during normal business hours
- Not having personnel readily available to assist with the delivery or pickup function
- Not having access to loading dock or platform
- Sites where carriers are delayed with security related inspections and processes prior to freight tender
Did you know: Some of these high security locations will ask for a driver’s license and drivers have the right to refuse to do so? This causes the carrier to find a driver who is willing to do so, which in turn causes a domino effect or constraint on the daily operations of that particular terminal.
In order to avoid unexpected charges it is best practice to ask the consignee if they have a dock or way to unload the freight and ask them if they need a liftgate for delivery. Liftgates are commonly associated with limited access and if the consignee advises they don’t need a liftgate let them know that if the driver offers a liftgate and if it is used or signed for even though it was not used, there will be an additional fee charged to them.
Limited access fees can be assessed on both commercial and non-commercial delivery sites. Charges and what constitutes as a limited access will vary based on carrier, but here are some of the most common examples:
- Camps, Carnivals, Fairs
- Churches, Mosques, Synagogues, Temples
- Schools (not including colleges and universities)
- Colleges and Universities without a dock
- Medical/Urgent care sites without a dock
- Prisons
- Individual / Mini Storage Units
- Mines, Quarries, Natural Gas or Oil Fields
- Golf Courses, Country Clubs
- Nuclear Power Plants
- Military Bases/Installations
- Parks, Farms and Rural locations
- Courthouses
- Daycares
- Hotels, Motels, Retirement/Nursing Homes
- Restaurants
- Cemeteries
- Convents
- Amusement Parks
- Construction Sites
- Outdoor Flea Markets
Google Maps is a great tool that can be used to help explain whether or not a location has limited access. However, please keep in mind that even though the location is easy to get in and out of and they may have the necessary equipment to unload they may still be considered limited access. Some great examples of this are as follows:
- Farms: While they are easy to get to and have equipment, they usually take the driver off his/her usual route which causes delays for the other shipments on the trailer
- Mini Storage Units: The driver will have to use a smaller trailer with or without a liftgate and thus make fewer deliveries that day because of the space available on the trailer, so the charges are there to compensate for this
- Carriers normally have fewer trailers with liftgates which makes this even more difficult when the volume of limited access or liftgate shipments goes up
Keep in mind: Commercial buildings with docks are normally clustered in the same area, a carrier can easily make multiple pickups or deliveries in a business park in the same time it may take to make one limited access delivery.